How can a slow temperature sensor smooth a gust-front passage?
A first-order sensor approaches a sudden air temperature change exponentially. After one time constant it has completed about 63% of the full adjustment.
Start with How do you build a contingency table for a supercell forecast?.
| Time after step | Model reading |
|---|---|
| 0 s | 24.00°C |
| 30 s | 18.94°C |
| 60 s | 17.08°C |
Set up the experiment
Hold the sensor initially at 24°C and force a sudden step to 16°C. Its time constant is 30 s. Predict whether the reading reaches 16°C after 30 s, then compute T = 16+8 exp(−t/30). At 30 s it reads 18.94°C. This assumes constant airflow response and a perfect step change in the surrounding air.
Practice questions
- What is the model reading after two time constants?
- When does the reading first reach 20°C?
- Why could a real gust-front passage differ from the step experiment?
Worked answers
Answer 1
16+8e⁻² ≈ 17.08°C.
Answer 2
8e^(−t/30) = 4, so t = 30 ln 2 ≈ 20.8 s.
Answer 3
Air temperature can change gradually and the sensor’s response can vary with ventilation or housing.
- 16+8e⁻² ≈ 17.08°C.
- 8e^(−t/30) = 4, so t = 30 ln 2 ≈ 20.8 s.
- Air temperature can change gradually and the sensor’s response can vary with ventilation or housing.