How do you calculate sensible heat flux beneath a developing storm?
The bulk sensible heat equation estimates the upward transfer from the surface to the air. It scales with wind speed and the surface-to-air temperature difference.
Start with How much evaporation does a given latent heat flux represent?.
| Surface minus air temperature | Wind speed | Heat flux |
|---|---|---|
| +4 K | 5 m/s | +24 W/m² |
| −4 K | 5 m/s | −24 W/m² |
Worked example
Use H = ρcpCₕU(Ts−Ta), where ρ is air density, cp is specific heat, Cₕ is a dimensionless transfer coefficient and U is wind speed at the specified reference height. With 1.2 kg/m³, 1000 J/(kg K), 0.001, 5 m/s and 4 K, H = +24 W/m². This exercise prescribes the coefficient, which can vary with roughness and stability.
Practice questions
- Double wind speed while holding the coefficient fixed.
- What does a negative result indicate here?
Worked answers
Answer 1
The estimate doubles to 48 W/m².
Answer 2
The modeled sensible transfer is toward the surface.
- The estimate doubles to 48 W/m².
- The modeled sensible transfer is toward the surface.