Supercell Simulator

Explore how instability, wind shear and cloud-base height affect a supercell environment. Change one ingredient and see how the calculations respond.

Jump to the storm cross-section

Atmospheric ingredients

2500J/kg
Energy available to accelerate an ideal rising parcel.
-50J/kg
Energy a parcel must overcome before it can rise freely. The necessary lift depends on the environment.
45kt
Magnitude of the vector wind difference between the surface and 6 km.
150m²/s²
Measures streamwise rotation available to a storm moving through the low-level wind profile.
1000m AGL
Height where a lifted surface parcel first becomes saturated.
68°F
Context for low-level moisture. CAPE and LCL are entered independently in this tool.

Model output

Convective inhibition describes how much help a parcel may need to rise. The trigger for a storm is outside this calculation.

STP
1.93
Sig. Tornado Param
EHI (0–1)
2.34
Energy-helicity
Ideal updraft
70.7
m/s, buoyancy only

Storm cross-section

Text description follows.
Minute 30 · Mature. Air rises through the tilted core while a separate downdraft descends.

The diagram shows an illustrative life cycle on a fixed scale. The orange arrow rises, the cyan arrow descends, and the pale blue arrow shows near-surface inflow. The timeline is independent of the environment calculations.

Compare environments

Show the math

Ideal updraft speed is √(2 × CAPE). EHI is CAPE × 0–1 km SRH ÷ 160,000.

Read a sample hodograph

This synthetic profile supplies wind components at four heights. The manual controls above accept bulk shear and helicity directly.

Sample wind profile
Height AGLEast (m/s)North (m/s)
0 km50
1 km56
3 km912
6 km1716

The 0–6 km vector difference is (12, 16) m/s. Its magnitude is 20 m/s. Helicity also depends on storm motion.

How this simulator works

These calculations describe the environment around a hypothetical storm. Official Enhanced Fujita ratings come from surveyed damage.

Fixed-layer STP. Multiply SBCAPE / 1500, the cloud-base factor, 0–1 km SRH / 150 and the deep-layer shear factor. The cloud-base factor is (2000 − LCL) / 1000, constrained between zero and one. The shear factor is zero below 12.5 m/s, then shear / 20 up to a maximum of 1.5. Convert knots to m/s before applying the thresholds. Reference formula.

The 0–1 km energy-helicity index is CAPE × SRH / 160,000. The ideal parcel updraft speed is √(2 × CAPE). Mixing, water loading and other processes affect real updrafts. CIN provides context for initiation and is separate from this STP variant.

With 2500 J/kg CAPE, a 1000 m cloud base, 150 m²/s² helicity and 45 kt shear, the storm environment has an STP of about 1.93. Raising the cloud base to 1500 m halves the cloud-base factor and lowers the index to about 0.96.

The six ingredients

Instability CAPE
Convective available potential energy measures the positive buoyancy available to a rising air parcel.
The cap CIN
Convective inhibition measures energy that must be overcome for a parcel to reach its level of free convection.
Deep-layer shear 0–6 km
A vector difference in wind over the first six kilometers above ground.
Storm-relative helicity SRH
The low-level contribution to storm-relative helicity depends on the wind profile and storm motion.
LCL height cloud base
The lifting condensation level estimates the base of a cloud produced by lifting a surface parcel.
Surface moisture Td
Dewpoint describes moisture. This tool accepts independent CAPE and LCL inputs, so changing dewpoint leaves the calculated outputs unchanged.

Try an illustrative environment

Choose a preset above the sliders, change one input and check the result. Presets are synthetic examples.

Read the illustrated supercell guides, including why rotation develops and where it happens in Southern Ontario.

Practice atmospheric science calculations or test how changing CAPE affects ideal updraft speed.

Try a supercell experiment

Related tools: damage simulator · Tornadle · weather trivia · live tornado index.